When a permit drawing is overlaid onto a survey, the first challenge is aligning the two coordinate systems. The process begins by matching property corners and monuments; these fixed points anchor the transformation before any structures are considered. Once the fit is established, structures that were clearly built out of place are set aside so they do not pull the alignment off. The review then displays the transform used—rotation, scale, and the fit error on the control points—allowing the reviewer to confirm each finding.

Naming and matching

Structures are matched by name. MH-1 matches MH-1, and SSMH #4 matches MH-4. Any item on the permit that the survey lacks is listed, and conversely, any item in the survey that does not appear on the permit is also recorded. This bidirectional check prevents assumptions that a missing permit entry is simply omitted.

Offsets and elevations

For each matched structure, the horizontal offset from its permit location is calculated. Rim, invert, and basin bottom elevation differences are also captured. Pipe length and slope changes are measured against the permit, and minimum cover is derived from ground shots in the survey.

Rule library

Keep specifications in one library, filed by State, County, City, then Utility or private entity. For example: North Carolina, Buncombe County, MSD. Choose the sets that apply to each project. Every rule holds a limit, a warning value, the document name, and the section. Each finding cites the document and section of the rule it broke. The app starts with common checks and placeholder numbers, which you replace with your own.

Worked example

The permit lists a manhole labeled MH-2. The survey contains a structure at the same coordinate but labeled MH-2A. The crosswalk records MH-2 → MH-2A, notes a 0.3‑ft horizontal offset, and an invert difference of +0.15 ft. The fit error on the control points is 0.02 ft, well within the acceptable threshold.

Decision rule

If the horizontal offset exceeds 0.5 ft or the invert difference exceeds 0.25 ft, flag the structure for field verification. Otherwise, accept the match and document the measured values.

Artifact

Sample crosswalk entry | Permit ID | Survey ID | Horizontal Offset (ft) | Invert Difference (ft) | Fit Error (ft) | Action | |-----------|-----------|------------------------|------------------------|----------------|------| | MH-2 | MH-2A | 0.30 | +0.15 | 0.02 | Accept |

Exception If the survey lacks a rim elevation but the permit provides one, record the permit value and note "rim elevation from permit; not verified in field."