AsBuiltReview

Investigating an unmatched manhole in a survey submittal

An unmatched structure is a question about identity before it is a question about compliance. Keep the permit identifier, survey point description and review status together until a reviewer can explain the match. Do not treat the nearest point as the intended structure just to clear a flag.

Trace one suspect pair

Imagine permit structure MH-7 does not match a survey point called SSMH-07A. Mark both on the same working view. Compare the connected runs, neighboring structure IDs and direction of travel along the network. Then check the source export for a suffix legend or field note. A nearby inlet on another run can look persuasive on a crowded plan.

Record three lines in the review log: Permit: MH-7; Survey candidate: SSMH-07A; Evidence: upstream/downstream connections agree; suffix not explained. That is a request for clarification, not a confirmed match. Keep the original labels intact. A guessed rename can change more than the label: every later comparison attached to that structure can appear valid.

What closes the finding?

Ask the survey or design lead for an identifier crosswalk or another traceable source. Record who resolved the identity and what they referenced. Only then use the matched pair for the numerical checks under the project's governing criteria.

One last check: can a reviewer who did not make the match reconstruct it without calling you? If all the log says is looks right, leave the issue open.