AsBuiltReview

Reviewing a survey with multiple inverts at one structure

A structure with several inverts is normal at a junction, a drop connection, or where pipes of different sizes meet. The review problem is not the count; it is keeping each invert attached to the right pipe. Record every invert with its pipe name and its role, then check the set as a whole.

Assign each invert to a named pipe

List the structure, then one line per invert: pipe name, invert elevation, and whether the pipe is incoming or outgoing. Where the survey names pipes and the permit names them differently, map the names in a small table before comparing. An unmapped invert is a finding, not a rounding issue.

Check the set for consistency

For a junction, the outgoing invert is normally the lowest, and incoming inverts sit above it. If the survey shows an incoming invert below the outgoing invert, that is worth a note even if each individual value matches the permit. Also check that the number of inverts matches the number of pipes crossing the structure wall.

A fictional example:

  • Structure SSMH-4, permit: incoming from MH-2 at 96.10; incoming from MH-3 at 96.40; outgoing to MH-9 at 95.80.
  • Survey: 96.12, 96.38, 95.79, plus an unlabeled invert at 95.70.

The comparison sheet maps the three named pipes, records differences against the stated tolerance, and flags the fourth invert as "unassigned — possible drop connection or abandoned pipe." The reviewer requests clarification rather than deleting it.

When the count does not match

If the permit shows two inverts and the survey shows four, do not force a match. Record the extra inverts, note the likely cause, and route the question to whoever holds the field records. A structure can genuinely gain a connection after the permit was drawn; the sheet should show that, not hide it.

Offline recordkeeping: every invert at the structure has a named pipe or an explicit unassigned flag, so the junction can be reviewed as a set.