Tracing one outlier without discarding the rest of a network
One bad value does not invalidate a network. The task is to isolate the outlier, show why it is an outlier, and keep the rest of the comparison intact. Quarantine the row; do not delete it and do not let it drive the fit.
Find the outlier by pattern, not by size
Look for the value that disagrees with its neighbors in a way the others do not. A single invert that is far from its pipe's other end, while every other pipe in the run is consistent, is a candidate. Record the candidate and the pattern that singled it out.
Quarantine the row and re-check the fit
Move the suspect value to a holding section of the sheet, marked "excluded pending check," with the reason. Recompute the affected pipe and the structure depth without it. If the rest of the network now reads consistently, the exclusion is supported; if not, the problem is larger than one row.
A fictional example:
- Run MH-10 to MH-14, inverts falling steadily by about 0.30 per structure.
- MH-12 survey invert reads 0.90 above MH-11, breaking the pattern.
- Sheet action: MH-12 invert moved to holding, reason "rises against flow; possible transposed digits."
- After exclusion, MH-10 to MH-14 reads consistently and the pipe slopes on either side of MH-12 are recomputed and shown.
The reviewer requests the field record for MH-12 and keeps the rest of the run in the comparison.
When the outlier is real
Sometimes the odd value is correct: a rebuilt structure, a corrected design, or a genuine high connection. If the field record supports it, restore the value, note the cause, and let the affected pipe slopes reflect it. The quarantine is temporary, not a verdict.
Offline recordkeeping: the suspect value sits in a labeled holding row with a reason, the rest of the network stays compared, and the decision on MH-12 waits for evidence rather than blocking the review.
Related: AsBuiltReview features.